Basic function

Basic function

  1. Electric characteristics: VF, DVF, VFD, VZ and IR
  2. Optical characteristics: LOP, λp, λd, λc, hw, purity, (x,y), CCT, CRI
  3. To avoid misjudgment, it is kelvin measurement and has the contact resistance function.
  4. Polarity determination and preheating function.
  5. It'sworkable for linking to automatic machine.
  6. It can connect with ESD. (Optional.)
  7. It's available for 4-dices in single package and it also has mix color test.可
  8. The device must have one pin in common.


Specific function

  1. The minimum of VF is 0.1uA.
  2. The maximum of VR is 200V.
  3. HBM mode is 8000V when linking to ESD.
  4. Data analysis. (LEDDispensing software only.)
  5. Yield observation and searching data. (LEDPreRealTime software only.)
  6. I-V curve function. (LED software only.)
  7. Operation is easy.
SPCIFICATION
Test
item

Reading
Output
item
Test condition
Remark
Unit
Range
Accuracy Reproducibility
UnitRange
Accuracy Output time
VF V 0.1~20.00 ±0.25%+0.002V ±0.02 IF mA 0.001~4.000 ±1%+0.002 2~99mS 1.2.8
4.01~40.00 ±1%+0.02 0.3~99mS
40.1~400.0 ±1%+0.2 0.3~99mS
401~2000 ±1%+2 0.3~99mS
DVF V 0.1~20.00 ±0.25%+0.002V ±0.02 DIF mA 0.001~4.000 ±1%+0.002 2~99mS 1.2.8
4.01~40.00 ±1%+0.02 0.3~99mS
40.1~400.0 ±1%+0.2 0.3~99mS
401~2000 ±1%+2 0.3~99mS
POLA Find polarity, no test reading
POLA
IF
mA 4.01~400.0 ±1%+0.2 1mS
HEAT Source only, no test reading
HEAT
IF
mA 0.001~4.000 ±1%+0.002 2~99mS 1.2.8
4.01~40.00 ±1%+0.02 0.3~99mS
40.1~400.0 ±1%+0.2 0.3~99mS
401~2000 ±1%+2 0.3~99mS
VFD V 0.1~20.00 Proximity
±0.1 IFD uA 100uA Proximity

1.2.8
mA 25mA
VZ V 0.1~200.0 ±0.25%+0.2 ±0.2 IZ uA 10.00~40.00 ±1%+0.02 2~99mS 1.2.8
40.1~400.0 ±1%+0.2 2~99mS
IR uA 0.001~4.000 ±1%+0.002uA ±0.005uA VR V 0.01~200.0V ±0.5%+0.02V 2~99mS 1.2.8
10.00~40.00 ±1%+0.02uA ±0.05uA
40.1~400.0 ±1%+0.2uA ±0.5uA
LOP
(Iv or Ie)

0.01~4.000 ±2% ±1% LOP
IF
mA 0.001~4.000 ±1%+0.002 2~99mS 1.3.8
4.01~40.00 ±2% ±1% 4.01~40.00 ±1%+0.02 0.3~99mS
40.1~400.0 ±2% ±1% 40.1~400.0 ±1%+0.2 0.3~99mS
Use calibration to correspond with Iv or Ie
401~2000 ±1%+2 0.3~99mS
λd nm 380.0~700.0 ±0.5nm ±0.3nm spec
IF
mA 0.001~4.000 ±1%+0.002 2~99mS 4.5.6.7.8
λc nm 380.0~720.0 ±0.5nm ±0.3nm 4.01~40.00 ±1%+0.02 0.2~99mS
λp nm 380.0~1000.0 ±0.5nm ±0.3nm 40.1~400.0 ±1%+0.2 0.2~99mS
HW nm 3.0~600.0nm ±0.5nm ±0.3nm 401~2000 ±1%+2 0.2~99mS
Purity
0.000~1.000 ±0.002 ±0.001 1.CD is 2048 pixel. 
  2.The least ST is 0.2 mS.
CIE x.y
0.0002~1.0000 ±0.001 ±0.0005
CCT °K 1000~25000 ±100 ±50
mix color test Test LOP and wavelength only.
spec
IFX4
mA 1.0~20.00 ±1%+0.02 1~99mS 4.5.6.7.8
20.1~200.0 ±1%+0.2 1~99mS
201~2000 ±1%+2 1~99mS


  • 1.In order to get normal test result for LED, please make sure it is not affected by heating and environment.
  • 2.When S/N is worse, it needs to use [50/60HZ]. The time of 50Hz needs higher than 20mS. The time of 60Hz needs higher than 16.6mS.
  • 3.Calibrated with a Standard LED with spectrum mismatch adjustment.
  • 4.λd, Purity and CCT are calculated from (x, y) refer to (x,y) for accuracy.
  • 5.A LED with flat spectrum width has worse λp accuracy.
  • 6.Using stanadrd UV lighting source to calibrate UV range of spectrum.
  • 7.λd is only referable for visible light.
  • 8.When current is lower, it needs to increase test time.


Dimension
Output curve





SPCIFICATION
Dimension  48.5(W)*52(L)*22(H)cm
Weight 18.98KG
AC input power 110V/220V
Watt 732W